DUPONT Electrodeionization Module Model EDI-310
DUPONT Electrodeionization Module Model EDI-310
Module Feed Water
Requirements
Based on RO Permeate
Feedwater
Parameter SI units US units
Hardness 0.01 meq/L ≤ 0.5 ppm (CaCO3)
Dissolved Silica ≤ 0.5 ppm
TOC ≤ 0.5 ppm
pH, Operating Range 5.0 – 9.0
Free Cl2 ≤ 0.05 ppm
Fe, Mn ≤ 0.01 ppm
Turbidity, NTU ≤ 0.1 ppm
Oxidizer, mg/L Not detectable
Module Operating
Conditions
Dilute Water Flowrate 1.5 – 2.2 m3/h 6.6 – 10 gpm
Recovery Rate up to 95%
Inlet Temperature 10 – 38°C 50 – 100°F
Inlet Pressure, max. 6.9 bar 100 psig
Continuous Operating Pressure, max. 5.5 bar 80 psig
Dilute Pressure Drop 1.5 – 2.5 bar 22 – 36 psig
Concentrate Outlet Pressure 0.5 – 0.7 bar less
than dilute pressure
7– 10 psig bar less
than dilute pressure
Electrolyte Flush 40 – 60 L/h 0.18 – 0.26 gpm
Electrical Current, max. 9A
Working Voltage, max. 160V DC